Benchmark Problems for Acoustical Parameters

Basic: A-12

Find values of reverberation time (T), early decay time (EDT), clarity (C80) and center time (Ts) from following impulse response.

a12.wav (RIFF waveform, 16 bit signed integer, monoral, sampling frequency: 48000 Hz)
a12.fb (floating-point binary (little endian), 144000 data, monoral, sampling frequency: 48000 Hz)
a12_wf

Note

This benchmark's impulse response is modified white noise exponentically to fit about 1.5 seconds of reverberation time.

Reverberation Time: T (s)

残響時間のグラフ,回帰区間を併記,数機関の結果
125 250 500 1k 2k 4k Regression interval
Okubo 1.501.601.581.501.501.50 -5 ~ -35 dB (T30)
Yasuda 1.511.601.581.501.501.50 -5 ~ -35 dB (T30)
Miyazaki 1.521.601.581.501.501.50 -5 ~ -35 dB (T30)


Early Decay Time (s)

残響時間のグラフ,回帰区間を併記,数機関の結果
125 250 500 1k 2k 4k
Okubo 1.821.301.461.531.541.56
Yasuda 1.821.311.461.531.541.56
Miyazaki 1.841.311.481.511.511.55


Clarity: C80 (dB)

C80
125 250 500 1k 2k 4k
Hoshi 2.191.240.40-0.600.080.53
Miyazaki 2.281.170.49-0.600.100.51


Center Time: Ts (s)

Ts
125 250 500 1k 2k 4k
Hoshi 0.1060.1000.1090.1150.1120.110
Miyazaki 0.1100.1060.1100.1160.1120.111
Yairi 0.0980.100.100.110.110.11